Universal measuring instrument for non-contact measurement on uneven surfaces, rotating parts, bearings, current-carrying parts, etc.
Type T2 / T4: optional connection of external sensor
168070Designs:168320.0100:
1-point laser sighting
Optics 10:1 (1m = Ø 116 mm)
Accuracy:*²
±2 °C or ±2 %*¹ (-30...0 °C)
±1.5 °C or ±1.5 %*¹ (+0.1...+400 °C)
168320.0200:
2-point laser sighting
Optics 12:1 (1m = Ø 100 mm)
Accuracy:*²
±2 °C or ±2 %*¹ (-30...0 °C)
±1.5 °C or ±1.5 %*¹ (+0.1...+400 °C)
Accuracy with probe:
±(0.5°C +0.5%*¹)
168320.0300:
2-point laser sighting
Optics 30:1 (1m = Ø 36 mm)
Accuracy: *²
±2 °C (-30...20.1 °C)
±1.5 °C (-20...0 °C)
±1 °C or ±1 %*¹
Accuracy with probe:
±(0.5 °C +0.5 %*¹)
Features:- Backlit display
- Adjustable alarm limits
- Audible/visual alarm
- Adjustable emissivity 0.20...1.0
Package contents:Delivered in transport packaging.
Appropriate batteries:
1 pieces
155050.0700 - 6LR61 / 9 V (included in scope of delivery).
*¹ of the measured value
*² the higher value applies
*³ with sensor (t99:
Time until sensor shows a 99% accurate value on the display)